İçeriğe geç
Industrial Process Control

Free Your Facility from Vendor Lock-In

We modernize your aging closed-box systems using a «Phased Rollover» approach — without halting facility operations. Manage your entire site with sub-second response times through open industry protocols, with no hidden licence renewal fees or Tag (sensor) limits.

Iskay SCADA & BMS in real-world use

Comprehensive Mechanical & HVAC Control

Far beyond ordinary relay logic — real-time (RTOS) control algorithms delivering the millimetric precision demanded by fluid dynamics.

Air Handling Unit (AHU) Management

Reads and controls dynamic air pressure (Pa/mbar) on fresh-air, supply and exhaust ducts, alongside PT1000-grade temperature data, through 16-bit analogue layers with millimetric precision.

Boiler Room & Chiller

Modulates proportional PID loops (0-10 V / 4-20 mA) in real time to improve the energy efficiency of circulation pumps and compressors in heating and cooling groups (chiller/boiler).

Inverter (VFD) Cascade Synchronisation

The instantaneous frequency (Hz) capacity of inverters on intake and supply motors is continuously read, ensuring fully synchronised (cascade) motor operation without disturbing the system pressure balance.

Safety & Mechanical Interlock

Freeze-stat, differential filter-fouling switches (DPT) and fire/smoke sensor data are monitored by a hardware watchdog; in the event of danger, the system transitions to «Safe State».

Zero Downtime, Maximum Cybersecurity

VLAN failures and sudden traffic bottlenecks on the general IT backbone of hospitals, factories or office buildings cannot jeopardise your critical facility. Discover our dedicated closed-loop network architecture.

Network Isolation (OT / IT Separation)
KVKK & ISO 27001

The automation (OT) network is fully isolated from the general IT network. External access is provided through a Reverse Proxy and an advanced firewall with DDoS filtering.

Asynchronous Data Processing (Delta T)
Smart Data Acquisition

Raw data from thousands of field sensors does not strain the server. Only changed values (Delta T) are processed, reducing response times to milliseconds (ms) and enabling a «Zero Downtime» Master-Slave scenario.

Bring the Power of Software to the Field

Invest in the future of your business with an adaptable, unlimited licensing model and cross-platform flexibility for every facility.

Hardware-Agnostic (Open Protocol)

We do not lock you into a single brand. We communicate directly with all field devices — from Modbus TCP/RTU-enabled industrial PLCs to ARM-architecture controllers.

Unlimited Licensing (No Limits)

Unlike competitors, you will never pay extra licence fees for the number of users, HMI screen designs or the count of I/O (Tag) points read from the field.

Dynamic Alarm Matrix

When the critical thresholds you define (temperature, pressure, motor fault) are exceeded, the system instantly alerts the relevant technical personnel via SMS, e-mail or push notification.

Granular (Role-Based) Access Control

Restricted permissions such as «View setpoints in own area only» can be assigned to specific personnel, preventing unauthorised panel interventions and system failures.

What's Included — Core Modules

From field communication to the rule engine, from access control to the live monitoring dashboard — every layer of the system comes together in a single solution. There is no need to purchase modules separately; every capability your facility needs is included out of the box.

Field Communication (RS485 + TCP)

  • Direct device polling over an RS485 serial line using a proprietary hex frame protocol (address, command, checksum byte)
  • Mixed-mode communication with TCP/IP field devices; serial and network devices in the same system
  • Automatic discovery, selection and authorization of USB/serial ports on Linux
  • Timeout and retry management for sending commands and reading responses at a fixed 9600 baud rate
  • Filtering out its own echo to process only genuine device responses

Rule Engine and Automation

  • Threshold-based rules: triggered when a sensor value exceeds or falls below a defined target (>, <, =, ≠)
  • Time-triggered rules: scenarios that run automatically at a set time (HH:mm)
  • Rule-bound actions: switching relays on, switching relays off and sounding a siren
  • Defining a delay time and an active duration for each action
  • Persistent tracking of trigger states to prevent the same event from firing repeatedly

Sensor and Relay Monitoring

  • Real-time reading of temperature, smoke and liquid-level sensors
  • Status tracking of multiple relays in a single packet via bit mask (on/off)
  • Assigning a custom name, unit and hardware code to each sensor
  • Per-device online/offline status, last contact time and last error message
  • Automatic OFFLINE marking after three failed attempts, with communication logging

Energy Monitoring Dashboard

  • Real-time status reading of the energy device over TCP
  • Reading and writing energy device settings
  • Changing the operating mode remotely
  • Relay states transferred to the dashboard as JSON and reflected live

Door and RFID Access Control

  • Manually triggering the door remotely
  • Configurable door open duration and buzzer (warning) duration
  • Bulk synchronization of the authorized RFID card list to the field device
  • Live monitoring of door and siren status

Command Protocol and Live Dashboard

  • UI-to-agent communication over a line-based command protocol on port 8081
  • Retrieving all field data and device logs as an instant in-memory dump
  • Adding manual relay commands and changing the operating port from the dashboard
  • Field data kept in memory for sub-second response without straining the database

Uninterrupted Operation

  • Runs continuously in the background as a Linux service (daemon)
  • Automatically reopens the serial port and resumes when the connection drops
  • Device configuration and rules are read from the central database
  • Port preference stored persistently in a local settings file

Time to Modernise Your Facility

Leave behind your ageing panels, worn sensors and proprietary software with heavy licence costs. Speak with our expert engineers for a turnkey project tailored to your facility.